Product Detail

Model No.: CMS60A
Packing: Packing Size:24*13.5*7 cm
Means of Transport: EMS,UPS,Fedex ,TNT, DHL
Delivery Date: 3-5 working days after rece...

Pediatric Pulse Oximeters
1.2.7' LCD display.
2.SPO2 measuring range:35-99%
3.Pulse Ratio:30-250BPM
4.AAA batteries*2

Pulse Oximeter 
CMS-60A Handheld Pulse Oximeter
 
CONTEC  CE Approved Handheld Pulse Oximeter Spo2 Monitor
Manufacturer: Contec Medical Systems
Model: CMS 60A Handheld Oximeter
Major applications and scope of application
The Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Technical specifications
1  Main performance
A.  SpO2 value display
B.  Pulse rate value display, bar graph display
C.  Pulse waveform display
D.  Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
E.  Screen brightness can be changed
F.  A pulse sound indication
G.  With alarm function
H.  It can be connected with an external oximeter probe
I.  Real-time data can be transmitted to computers
2  Main Parameters
A.  Measurement of SpO2
Measuring range: 0%~100%
Accuracy:
When the SpO2 measuring range is 70%~100%,the permission of absolute error is ±2%;
below 70% unspecified
B.  Measurement of pulse rate
Measuring range:25bpm~250bpm
Accuracy: ±2 bpm or ±2% (select larger)
C.  Resolution
SpO2 : 1%, Pulse rate: 1bpm.
D.  Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
E.  Resistance to surrounding light:
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
F.  Power supply requirement: : 2.6 V DC ~ 3.6 V DC.
G.  Optical Sensor
Red light (wavelength is 660nm,6.65mW)
Infrared  (wavelength is 880nm,  6.75mW)
Contents
A.  1 oximeter probe
B.  2 batteries 
C.  1 User Manual
D.  1 data line (optional )
E.  1 disk (PC software)(optional )

 
Wattanty
All items are brand new, with 3 years warranty and whole life repair
 
Certificate
CE & ISO
 
 
 
About Us
Contec Medical Systems in an original medical equipment manufactory based in China. We focus on researching, manufactorying and distributing of medical instruments.
 
Main Products
Pulse Oximeter, Fetal Doppler, Patient Monitor, Stethoscope, B-Ultrasound, EEG/EEG Holter, ECG/ECG Holter, etc.
bigPhoto
 Ms. Ella Yang

Tel: 86-335-8015417
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Qinhuangdao Contec Medical Systems Co.,Ltd [China (Mainland)]


Country/Region: China (Mainland)

You May Like: